enLanguage

LNG Ambient Air Temperature Vaporizer Unloading Pressurization Process

Jan 30, 2023 Leave a message

1. Put the LNG tank car in place, connect the ground wire, and notify the tanker driver to connect the LNG tank car with the LNG tank car unloading liquid hose, unloading platform liquid hose and gas hose.
2. Open the front release valve of the tank truck unloading supercharger, the unloading supercharger valve, and the tank car booster gas phase valve.
3. Notify the tanker driver to open the booster gas valve of the tanker to replace the booster system of the tanker.
4. When the discharge valve port is frosted, close the discharge valve before the unloading supercharger.
5. Start the LNG unloading supercharger to increase the pressure of the LNG tank car to 0.55Mpa.
6. Inform the driver of the tanker to open the liquid inlet valve of the LNG tanker, open the vent valve of the liquid phase pipe, and replace the air in the pipe at the place where the liquid phase pipe is vented. Close the liquid phase vent valve after frost has formed in the liquid phase vent.
7. Open the liquid inlet valve on the LNG storage tank, the emergency cut-off valve of the liquid inlet pipe, and the main liquid inlet valve, open up the liquid inlet process on the LNG storage tank, pre-cool the liquid inlet pipeline of the storage tank, and slowly fill the storage tank with LNG.
8. After the pressure of the LNG storage tank does not rise, gradually open the lower liquid inlet valve of the LNG storage tank, slowly increase the filling speed of the LNG storage tank, and pay attention to the changes in pressure and liquid level.
9. After the LNG in the LNG tanker is unloaded, close the lower inlet valve of the LNG storage tank, open the upper inlet valve of the LNG storage tank, and purge the LNG tanker hose and the LNG in the pipeline with the LNG gas phase in the LNG tanker to LNG storage tanks.
10. Close the main liquid inlet valve of the storage tank, open the gas-liquid balance valve to release the pressure of the unloading pipeline to the BOG system through the gas phase line, when the gas phase in the tank car cannot be unloaded, close the liquid inlet valve of the LNG tank car, and open the front-end vent valve , vent the LNG gas phase in the hose of the LNG tanker, open the gas-liquid valve, and close it after equalizing the pressure.
11. If leakage occurs during the unloading process, the emergency shutdown button should be pressed and corresponding emergency measures should be taken.
12. In case of lightning strikes, failure of liquid unloading equipment, or accidents around the gas filling station that cannot guarantee normal operation, liquid unloading should be suspended.

https://www.chinavaporizer.com/

Send Inquiry

whatsapp

Phone

E-mail

Inquiry