1. Check the liquid root valve at the bottom of the storage tank to ensure that it is in the normally open state, and the outlet valve of the air-temperature vaporizer is in the open state.

2. Open the liquid inlet valve and liquid outlet emergency shut-off valve of the air-temperature evaporator, and then slowly open the main liquid outlet valve.

3. When opening the main liquid outlet valve, the flow rate should be controlled well, and the valve opening should be adjusted until the gasification amount reaches the requirement.

4. If condensation, frost, or ice is found in the air outlet pipe, causing the outlet air temperature to be too low, it indicates that the liquid inlet is too large, and the liquid inlet valve must be closed immediately to prevent excessive liquid.

5. When the air-heated carburetor continues to operate, if the outlet temperature is lower than the ambient temperature (8-10) degrees, it should be switched to another group of carburetors.